Deck · Structure

Deck Load Calculator

Where the weight goes: total, beam, ledger and post loads from the IRC design loads, the footing area your soil needs, and a hot-tub reality check.

Code basis: 2021 IRC R301.5, R401.4, R507Sources

1 Deck
ft
ft
ft
2 Loads and soil
psf
IRC Table R301.5: 40 for decks
psf
DCA 6 uses 10
psf
From your building department
Design load
50psf
10 dead + 40 live
Whole deck
9,600lb
192 ft²
Interior post
2,400lb
48.0 ft² tributary
Footing area
1.60ft²
≈ 18 in. round on 1500 psf soil
Load path
MemberLoadHow
Beam load4,800 lbwidth × (½ joist span + cantilever) × psf
Ledger load4,800 lb300 lb per foot of ledger
Post spacing8′3 posts, even bays
Guards must also resist a 200 lb concentrated load (IRC Table R301.5). Size each footing in the footing calculator, which applies the IRC R507.3.1 table.

How deck loads flow

Load travels from the decking to the joists, from the joists to the ledger and beam, from the beam to the posts, and from each post to its footing and the soil. Each piece carries its tributary area: the patch of deck whose weight lands on it. On an attached deck, the ledger takes the house half of the joist span and the beam takes the other half plus any cantilever.

house / ledgertributary of the middle post½ joist span
The middle post carries the shaded area: half the bay on each side and half the joist span.
Design load = dead (10 psf) + max(live 40 psf, ground snow) Beam load = width × (joist span ÷ 2 + cantilever) × design load Ledger load = width × (joist span ÷ 2) × design load Middle post = post spacing × (joist span ÷ 2 + cantilever) × design load Footing area = post load ÷ soil bearing (IRC Table R401.4.1)

Worked example: 16 × 12 ft attached deck, three posts

  • Design load 50 psf; whole deck 192 ft² × 50 = 9,600 lb.
  • Beam: 16 × 6 × 50 = 4,800 lb. Ledger: the same 4,800 lb, 300 lb per foot.
  • Middle post: 8 ft × 6 ft = 48 ft² × 50 = 2,400 lb.
  • On 1,500 psf clay: 2,400 ÷ 1,500 = 1.6 ft² of footing, about a 17 in. round footing (18 in. in practice).
  • Add a 400-gallon hot tub: 4,636 lb on 49 ft² = 95 psf, beyond what the deck tables cover.

Using the numbers

This calculator explains where the load goes; it doesn’t size members. For a code-referenced design, use the joist span, beam and post and footing calculators, which apply the 2021 IRC deck tables directly, or the full deck planner. Anything outside those tables, such as hot tubs, roofs, privacy walls or heavy planters, needs an engineered design. Check with your local building department before you build.

Common misunderstandings

  • “40 psf means 40 lb per square foot anywhere.” It is a uniform design load. A grill, a planter or a crowd at the rail concentrates load; guards must also resist 200 lb at any point.
  • Ledgers are the weak point. Most deck collapses start at the ledger connection. Its fasteners must follow R507.9 and go into a solid band joist.
  • Footings are sized by soil, not by habit. The same post load needs a bigger footing on clay (1,500 psf) than on gravel (3,000 psf).

Where heavy items can go

If you want a heavy planter, an outdoor kitchen or a big grill station, put it near a beam or the ledger, not in the middle of a long joist span, and keep it off cantilevers. For anything that approaches the design load over its footprint, run the numbers here and ask your building department whether it needs a designed connection or its own footings.

Questions people ask

How much weight can a deck hold?
Decks built to the IRC prescriptive rules are designed for a 40 psf live load (Table R301.5) plus a 10 psf dead load, 50 psf in total. A 16 × 12 ft deck is therefore designed for about 9,600 lb spread evenly, not for heavy concentrated items like a hot tub.
Can my deck hold a hot tub?
Usually not without engineering. A 400-gallon tub weighs over 3,300 lb in water alone; with the shell and four people it is about 4,600 lb. On a 7 × 7 ft footprint that is about 95 psf, nearly double the 50 psf the prescriptive tables assume. Hot tubs need an engineered frame and footings, or their own slab.
How much load does each deck post carry?
Each post carries its tributary area times the design load. On an attached 16 × 12 ft deck with a beam on three posts, the beam carries half the 12 ft joist span; the middle post’s tributary area is 8 × 6 = 48 ft², or 2,400 lb at 50 psf. End posts carry about half that.
Does snow load count?
Yes. The IRC deck tables use the larger of the 40 psf live load and the ground snow load. Where snow exceeds 40 psf, it governs; the 2021 IRC deck tables cover up to 70 psf, and the calculator uses whichever is larger.

Sources

  1. 2021 International Residential Code (IRC) — International Code Council, checked Nov 2026.
  2. DCA 6: Prescriptive Residential Wood Deck Construction Guide — American Wood Council, checked Nov 2026.

Related calculators

All deck tools →